This email address is being protected from spambots. You need JavaScript enabled to view it.
Three-level frequency converter
MFC 810 type
55- 800 kW
1140 V
The drive MFC810 series is designed to control induction motors with a rated voltage 1000/1140V.
Modular design, 3-level topology and a liquid cooling system predispose this series for installation in areas with relatively low cubature.
Main features:
- Three-phase supply: 3x1140 V 50/60 Hz
- Output: 0 – 100 Hz, 3 x 1140 V
- Advanced control modes:
U/f (linear, square-law scalar),
Vector mode (sensor or sensorless) - Removable operating panel with LCD alphanumeric display
- Integrated Logic Controller (PLC)
- Built-in "reeler-calculator"
- Built-in pump or fan set controller
- Integrated PID controller
- Embedded communication module RS232/RS485 (Modbus)
- Programmable fixed frequencies
- Digital potentiometer function
- Direct rotational (or linear) incremental encoder (5V line interface)
- Elimination of resonance frequencies bands
- Definable shapes and slopes of selected frequency characteristic (linear, "S"-shaped)
- Allowable work with torque control
- Automatic identification of motor parameters
- Programmable control structure:
- two customizable control variants (A & B):
- speed selector block (control panel, analog input, PID controller, digital potentiometer, function block),
- torque selector block(analog inputs, function block),
- run and direction control (control panel, digital input, function block),
- programmable digital inputs: run, direction, run blockade, external trip, trip cancellation,
- programmable digital outputs: ready, run, fault, warning, overtemperature of heatsink, given speed reaching, threshold speed reaching, current limit, function block),
- programmable analog outputs: frequency, rotational speed, output current, voltage, loading of motor, function block.
- Total work counter (hours)
- Real-time Clock (optional)
- Diagnostic and blockade system
- Control panel protection with system of passwords
- Memory for 4 motors parameters
- Allowable use of default values for all parameters
Download User manual - hardware
Download User manual - software